home > sell > Supply JTY-GM-JLDS point type smoke fire detector quality assurance
Supply JTY-GM-JLDS point type smoke fire detector quality assurance
products: Views:8Supply JTY-GM-JLDS point type smoke fire detector quality assurance 
brand: 立安鑫
工作电压: 15-32V
工作温度: -10℃~+50℃
相对湿度: ≤95%,不结露
price: 1.00元/个
MOQ: 1 个
Total supply: 10000 个
Delivery date: Shipped within 1 days from the date of payment by the buyer
Valid until: Long-term validity
Last updated: 2016-12-30 11:07
 
Details
Point type smoke fire detector
.
Introduction
Point type smoke fire detector is a photoelectric smoke detector developed using the principle of infrared scattering. The detector adopts modern technology and uses a microprocessor chip and non-volatile memory inside. It has powerful processing functions and accurate and reliable alarms. The smoke sensing parameter simulation quantity collection and processing, and the internal intelligent model criteria make up for the shortcomings of the traditional alarm mechanism. The microprocessor enables the detector to compensate for environmental changes through dynamic zero adjustment and differential correction technology.
.
Main features and technical indicators:
◆Wire system: non-polar two buses
◆Encoding method: electronic writing code, simple and convenient operation
◆Structural design Reasonable, effectively resist the influence of dust pollution and humid air, and the shape is round and beautiful
◆Advanced three-proof processing technology, effectively resist the erosion of moisture, mildew, salt spray, etc.
◆Built-in dust cover, with Dust-proof, insect-proof and anti-interference performance
◆Working voltage:
Bus pulse
◆Working current: monitoring current, alarm current
◆Using environment: temperature~+℃
/>, relative humidity %
~% (no condensation)
◆Dimensions: diameter, height
◆Weight
◆Alarm confirmation light: red
◆Casing Material and color: B beige
◆Detector status display
Normal monitoring status: The light flashes periodically Fire alarm status: The light is always on Fault status: The light is often off or flashes irregularly
◆Protection area: When the space height is , the protection area of a detector for general protection is . When the space height is below , the protection area is , and the specific parameters should be based on the "Design Specification for Automatic Fire Alarm System B".
.
Wiring and installation
Wiring requirements: The insulation resistance between lines and between lines and the ground is greater than 1, and the resistance of a single line of the detection bus loop is less than 1.
The two detectors are connected in parallel.
The bus loop of this system adopts a two-wire system, regardless of polarity. There is a conductor piece on the detector base with wiring terminals. When wiring, crimp the two bus lines of a certain circuit to the terminals of the detector base.
After the base is firmly installed, connect the bottom of the detector Align the base and rotate it clockwise to install the detector on the base.
The detector should be encoded with an electronic encoder before installation.